Automatic Air Vent Valves for Liquid Cooling Systems

Automatic air vent valves for pipeline high points in CDU and rack-level cooling circuits — removing trapped air that reduces efficiency and accelerates corrosion.
Choose Your Configuration
Automatic air release for CDU piping peaks, return headers and rack-level cooling loop high points, helping reduce trapped-air accumulation during filling and operation.
Not Sure Which Valve Fits Your Cooling Loop?
Every cooling loop has unique isolation requirements. Describe your application and our engineers will recommend the right butterfly valve type and configuration.
Our Advantages
The QINFENG Valve Difference
One-Piece Welded Body
One-Piece Welded Body
Valve body precision-welded into a single integrated structure — eliminates threaded joint leak paths. No mechanical connections mean zero external leakage risk over the system lifetime.
Zero Leakage, Automatic Operation
Zero Leakage, Automatic Operation
Float-type mechanism opens to vent air and seals tight when water reaches the valve. Helium leak-tested body ensures no coolant loss — fully automatic, zero manual intervention.
They Chose QINFENG:

Quality Assurance

Air vent valves undergoes 100% shell pressure testing and float mechanism verification. Filter screen integrity inspected. Material confirmed by spectrometer analysis. Test reports available upon request.

Every hygienic valve undergoes 100% shell hydro and seat leakage testing — zero bubbles equals zero leak
Every hygienic valve undergoes 100% shell hydro and seat leakage testing — zero bubbles equals zero leak
Every hygienic valve undergoes 100% shell hydro and seat leakage testing — zero bubbles equals zero leak
Every hygienic valve undergoes 100% shell hydro and seat leakage testing — zero bubbles equals zero leak

* All exhaust valves are 100% tested before shipment.

What we provide
What we provide:

Valve sizing by your flow and pressure specs. Material compatibility analysis for your coolant type. Custom end connections (Tri-Clamp, weld, flange). Actuator selection support (manual, pneumatic, electric).

Frequently Asked Questions
Please let us know your basic requirements. Our technical team will respond within 24 hours.
Contact Us

Why are automatic air vent valves needed in liquid cooling systems?

 
 

Trapped air at pipeline high points creates air pockets that reduce cooling efficiency and accelerate system corrosion. Automatic exhaust valves vent this air without manual intervention, maintaining optimal thermal performance.

How does a float-type exhaust valve work in cooling circuits?

 
 

The float-type mechanism rises with water level to seal the valve and drops when air accumulates to release it. Fully automatic operation — no manual bleeding required at CDU piping peaks or rack-level high points.

Why use stainless steel exhaust valves instead of brass alternatives?

 
 

Stainless steel construction resists corrosion from deionized water, glycol mixtures, and fluorinated coolants. No material degradation or contaminant release into high-purity cooling circuits over the system lifetime.

How does the built-in filter screen protect exhaust valve performance?

 
 

Integrated filter screen prevents suspended particulates from entering the valve mechanism, eliminating clogging and sticking. Ensures stable long-term operation even in systems with debris present.

Latest Updates
QINFENG Launches Enhanced One-Piece Welded Butterfly Valve Series for AI Data Center Liquid Cooling
New Valve Series Addresses Zero-Leakage Requirements in High-Density RacksAs AI server racks push power densities beyond 50kW, liquid cooling system operators face increasing pressure t
2026.06.15
QINFENG Completes High-Volume Delivery of Prefabricated Liquid Cooling Piping Modules
Factory Pre-Assembly Accelerates On-Site Installation for Multiple Data Center ProjectsQinfeng Technology has successfully delivered over 1,500 prefabricated liquid cooling piping modul
2026.06.15
Grand Opening of WAIC 2026 | Liquid Cooling Takes Center Stage as Phase-Change Solutions Steal the Spotlight on Debut Day
From Air-Cooled to Liquid-Cooled, Phase-Change Technology Redefines the New Era of Computing Power CoolingShanghai, July 2026 — Amid the dazzling AI applications on display at the World Artificial Int
2026.07.29
Find the Right Valve Solution for Your Cooling System
Contact Us
How we can help you:
  • Valve sizing, material compatibility, and flow path optimization
  • Prefabricated manifold and piping system design
  • 24-hour CAD drawings and sample support

GET A QUOTE

+86 86998350

[email protected]

GET IN TOUCH NOW